Reasonable price for 20411 Swaged Hose Fiting to Boston Manufacturer

Short Description:

O’RING METRIC FEMALE 24° CONE LIGHT TYPE DIN 3865 (DKOL)    PART NUMBER HOSE THREAD T PIPE B mm L mm A mm H2 mm   DN In SIZE             S204A1 – 03 – 12 5 3/16″ 03 M12x1,5 6 3 24,1 1,2 14 S204A1 – 04 – 14 6 1/4″ 04 M14x1,5 8 4 24,5 1,8 17 S204A1 – 04 – 16 6 1/4″ 04 M16x1,5 10 5,5 26 2,3 19 S204A1 – 05 – 16 8 5/16″ 05 M16x1,5 10 5,5 26 2,3 19 S204A1 – 05...


Product Detail

Product Tags

Related Video

Feedback (2)

By using a sound small business credit, excellent after-sales provider and modern producing facilities, now we have earned an exceptional track record between our clients across the whole world for Butt Weld Fittings , Hydraulic Tube Fittings , Hydraulic Pipes And Fittings , We have now built a trustworthy track record amid many shoppers. Quality&customer 1st are normally our constant pursuit. We spare no endeavours to produce greater products. Anticipate long-term cooperation and mutual rewards!
Reasonable price for 20411 Swaged Hose Fiting to Boston Manufacturer Detail:

O’RING METRIC FEMALE 24° CONE LIGHT TYPE DIN 3865 (DKOL) 

4

 

PART NUMBER

HOSE

THREAD

T

PIPE

B

mm

L

mm

A

mm

H2

mm

 

DN

In

SIZE

 

 

 

 

 

 

S204A1 – 03 – 12 5 3/16″ 03 M12x1,5 6 3 24,1 1,2 14
S204A1 – 04 – 14 6 1/4″ 04 M14x1,5 8 4 24,5 1,8 17
S204A1 – 04 – 16 6 1/4″ 04 M16x1,5 10 5,5 26 2,3 19
S204A1 – 05 – 16 8 5/16″ 05 M16x1,5 10 5,5 26 2,3 19
S204A1 – 05 – 18 8 5/16″ 05 M18x1,5 12 7 26 2,5 22
S204A1 – 06 – 18 10 3/8″ 06 M18x1,5 12 7 26,6 2,5 22
S204A1 – 06 – 22 10 3/8″ 06 M22x1,5 15 9,5 30,1 2,5 27
S204A1 – 08 – 22 12 1/2″ 08 M22x1,5 15 9,3 29,3 2,5 27
S204A1 – 08 – 26 12 1/2″ 08 M26x1,5 18 12 31,3 2,5 32
S204A1 – 10 – 26 16 5/8″ 10 M26x1,5 18 12 30,3 2,5 32
S204A1 – 12 – 30 20 3/4″ 12 M30x2 22 15 33 3,5 36
S204A1 – 12 – 36 20 3/4″ 12 M36x2 28 19,5 34,5 3,7 41
S204A1 – 16 – 36 25 1″ 16 M36x2 28 19,5 34,3 3,7 41
S204A1 – 20 – 45 32 1.1/4″ 20 M45x2 35 26 39 4 50
S204A1 – 24 – 52 40 1.1/2″ 24 M52x2 42 32 39,5 4,5 60
S204A2 – 06 – 16 10 3/8″ 06 M16x1,5 10 5,5 23,6 2 19

Product detail pictures:

Reasonable price for 20411 Swaged Hose Fiting to Boston Manufacturer detail pictures

Reasonable price for 20411 Swaged Hose Fiting to Boston Manufacturer detail pictures


Related Product Guide:
Understanding Hydraulic Hose Fittings
Importance of PVC Fittings

We are ready to share our knowledge of advertising worldwide and recommend you suitable goods at most aggressive selling prices. So Profi Tools present you best price of money and we are ready to produce together with Reasonable price for 20411 Swaged Hose Fiting to Boston Manufacturer, The product will supply to all over the world, such as: Tunisia , Anguilla , Guyana , In the new century, we promote our enterprise spirit "United, diligent, high efficiency, innovation", and stick to our policy"basing on quality, be enterprising, striking for first class brand". We would take this golden opportunity to create bright future.


  • MCP-Detector on CF-Flange sales@dmphotonics.com
    MCP-MA25/2 mounted on a CF4.5″ flange

    Open Microchannel Plate Detector MCP-MA25/2 – always in stock!

    http://www.dmphotonics.com/MCP_MCPImageIntensifiers/mcpma252.htm

    Microchannel Plate Detectors MCP-MA series are an open MCP detectors with one or more microchannel plates and a single metal anode. They are intended for time-resolved detection and make use of high-speed response properties of the MCPs. MCP-MA detectors are designed for photons and particles detection in vacuum chambers or in the space. MCP-MA detectors are used in a variety of applications including UV, VUV and EUV spectroscopy, atomic and molecular physics, TOF mass–spectrometry of clusters and biomolecules, surface studies and space research.
    MCP-MA detectors supplied as a totally assembled unit that can be easily mounted on any support substrate or directly on a vacuum flange. They also can be supplied premounted on a standard ConFlat flanges.

    Del Mar Photonics has strong experience in the supply of Microchannel Plates (MCP) and MCP detectors for variety of applications.

    Please tell us about your application and requirements so we can answer with detailed proposal in a timely manner:

    1. What type of particles/photons you plan to detect?

    2. What is the expected energy of the particles at the entrance of MCP detector?

    3. Tell us about the flux of the particles: is it continuous or pulsed? how many particles per second or per pulse? in case of pulsed signal how long is the pulse and what is the pulse duration and repetition rate.

    4. Do you require detection or imaging of the particles? The required time resolution will detrming if you need standard or special fast anode.

    5. If you need to image or profile particle beam we offer MCPs together phosphor screens (standard P20, P43 and P47 as well as many others). Choice of phosphor is usually dictated by what readout (CCD or PMT) will be used.

    6. If you need fast imaging we can offer special phosphors – please indicate required imaging speed.

    7. Do you need stand alone or flange mounted MCP detectors with high voltage feedthroughs. In case of imaging applications flange mounted detectors are supplied on a viewport.

    8. What is the required active area of the detector?

    9. Do you required configurations with single, double or z stack MCP detectors? If you are not sure, your answers to the previous questions will help us to offer you the right configuration.

    http://www.dmphotonics.com/MCP_Detector_Basics/how_to_choose_mcp_detector.htm

    MCP-MA25/2 are used in aSPECT to study the background.

    1. Measuring the proton spectrum in neutron decay – latest results with aSPECT

    M. Simson, F. Ayala Guardia, S. Baeßler, M. Borg, F. Glück, W. Heil, I. Konorov, G. Konrad, R. Muñoz Horta, K.K.H. Leung, Yu. Sobolev, T. Soldner, H.-F. Wirth, O. Zimmer
    (Submitted on 24 Nov 2008)
    The retardation spectrometer aSPECT was built to measure the shape of the proton spectrum in free neutron decay with high precision. This allows us to determine the antineutrino electron angular correlation coefficient a. We aim for a precision more than one order of magnitude better than the present best value, which is Delta_a /a = 5%.
    In a recent beam time performed at the Institut Laue-Langevin during April / May 2008 we reached a statistical accuracy of about 2% per 24 hours measurement time. Several systematic effects were investigated experimentally. We expect the total relative uncertainty to be well below 5%.

    2. G. Konrad et al., “The Proton Spectrum in Neutron Beta Decay: Latest Results with the aSPECT Spectrometer”, Nucl. Physics A 827, 529c (2009)

    The Proton Spectrum in Neutron Beta Decay: First Results with the aSPECT spectrometer

    Baeßler, S.; Angerer, H.; Ayala Guardia, F.; Borg, M.; Eberhardt, K.; Glück, F.; Heil, W.; Konorov, I.; Konrad, G.; Luquero Llopis, N.; Muñoz Horta, R.; Orlowski, M.; Petzoldt, G.; Rich, D.; Simson, M.; Sobolev, Y.; Wirth, H. F.; Zimmer, O.
    INTERSECTIONS OF PARTICLE AND NUCLEAR PHYSICS: 9th Conference CIPAN2006. AIP Conference Proceedings, Volume 870, pp. 287-290 (2006).
    First measurements with the aSPECT spectrometer have been performed in a beam time at the beam line MEPHISTO of the neutron research reactor FRM-II. In this paper we give a short description of the spectrometer. The data analysis is underway.

    MCP detectors with metal anode are used in different applications. It is possible to detect and count electrons, positrons, protons, ions, Soft X-rays, x-rays, EUV,
    VUV- and UV-radiation.
    The flanges are equipped with 3 welded vacuum SHV high voltage feedthroughs.

    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Dolores from Czech - 2015.02.12 14:52
    The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Lynn from Estonia - 2016.12.31 14:53

    Related Products

    WhatsApp Online Chat !