14 Years Manufacturer P20511 one piece type to Hungary Factories

Short Description:

O’RING METRIC FEMALE 24° CONE HEAVY TYPE DIN 3865 (DKOS)   PART NUMBER HOSE THREAD T PIPE B mm L mm A mm H2 mm   DN In SIZE             P205A1 – 03 – 16 5 3/16″ 03 M16x1,5 8 3 26,1 4,4 19 P205A1 – 04 – 16 6 1/4″ 04 M16x1,5 8 4 26,6 4,4 19 P205A1 – 04 – 18 6 1/4″ 04 M18x1,5 10 4 28 3 22 P205A1 – 05 – 20 8 5/16″ 05 M20x1,5 12 5,5 28,1 2,5 24 P205A1 – 06 &...


Product Detail

Product Tags

Related Video

Feedback (2)

Our products are greatly recognized and trustworthy by users and will fulfill continually shifting economic and social requires for Hydraulic Fitting Kit Nsn, High Pressure Hose Fittings, Hydraulic Couplings Perth, We will do our best to meet your requirements and are sincerely looking forward to developing mutual beneficial business relationship with you!
14 Years Manufacturer P20511 one piece type to Hungary Factories Detail:

O’RING METRIC FEMALE 24° CONE HEAVY TYPE DIN 3865 (DKOS)

13

 

PART NUMBER

HOSE

THREAD

T

PIPE

B

mm

L

mm

A

mm

H2

mm

 

DN

In

SIZE

 

 

 

 

 

 

P205A1 – 03 – 16 5 3/16″ 03 M16x1,5 8 3 26,1 4,4 19
P205A1 – 04 – 16 6 1/4″ 04 M16x1,5 8 4 26,6 4,4 19
P205A1 – 04 – 18 6 1/4″ 04 M18x1,5 10 4 28 3 22
P205A1 – 05 – 20 8 5/16″ 05 M20x1,5 12 5,5 28,1 2,5 24
P205A1 – 06 – 20 10 3/8″ 06 M20x1,5 12 7 28,6 2,5 24
P205A1 – 06 – 22 10 3/8″ 06 M22x1,5 14 7 32,6 3,5 27
P205A1 – 08 – 24 12 1/2″ 08 M24x1,5 16 9,3 32,3 4,5 30
P205A1 – 10 – 30 16 5/8″ 10 M30x2 20 12 37,3 4 36
P205A1 – 12 – 36 20 3/4″ 12 M36x2 25 15 40,5 4,5 46
P205A1 – 16 – 42 25 1″ 16 M42x2 30 19,5 43,8 6,3 50
P205A1 – 20 – 52 32 1.1/4″ 20 M52x2 38 26 49,5 8 60

Product detail pictures:

14 Years Manufacturer P20511 one piece type to Hungary Factories detail pictures


Related Product Guide:
Things to Know About Pipe Fitting Works
Understanding Hydraulic Hose Fittings

owing to very good support, a variety of high quality merchandise, aggressive costs and efficient delivery, we love an excellent name among the our clients. We are an energetic company with wide market for 14 Years Manufacturer P20511 one piece type to Hungary Factories, The product will supply to all over the world, such as: Moscow, Suriname, Luxembourg, Our company always concentrate on the development of the international market. We've got a lot of customers in Russia , European countries, the USA, the Middle East countries and Africa countries. We always follow that quality is foundation while service is guarantee to meet all customers.


  • MCP-Detector on CF-Flange sales@dmphotonics.com
    MCP-MA25/2 mounted on a CF4.5″ flange

    Open Microchannel Plate Detector MCP-MA25/2 – always in stock!

    https://www.dmphotonics.com/MCP_MCPImageIntensifiers/mcpma252.htm

    Microchannel Plate Detectors MCP-MA series are an open MCP detectors with one or more microchannel plates and a single metal anode. They are intended for time-resolved detection and make use of high-speed response properties of the MCPs. MCP-MA detectors are designed for photons and particles detection in vacuum chambers or in the space. MCP-MA detectors are used in a variety of applications including UV, VUV and EUV spectroscopy, atomic and molecular physics, TOF mass–spectrometry of clusters and biomolecules, surface studies and space research.
    MCP-MA detectors supplied as a totally assembled unit that can be easily mounted on any support substrate or directly on a vacuum flange. They also can be supplied premounted on a standard ConFlat flanges.

    Del Mar Photonics has strong experience in the supply of Microchannel Plates (MCP) and MCP detectors for variety of applications.

    Please tell us about your application and requirements so we can answer with detailed proposal in a timely manner:

    1. What type of particles/photons you plan to detect?

    2. What is the expected energy of the particles at the entrance of MCP detector?

    3. Tell us about the flux of the particles: is it continuous or pulsed? how many particles per second or per pulse? in case of pulsed signal how long is the pulse and what is the pulse duration and repetition rate.

    4. Do you require detection or imaging of the particles? The required time resolution will detrming if you need standard or special fast anode.

    5. If you need to image or profile particle beam we offer MCPs together phosphor screens (standard P20, P43 and P47 as well as many others). Choice of phosphor is usually dictated by what readout (CCD or PMT) will be used.

    6. If you need fast imaging we can offer special phosphors – please indicate required imaging speed.

    7. Do you need stand alone or flange mounted MCP detectors with high voltage feedthroughs. In case of imaging applications flange mounted detectors are supplied on a viewport.

    8. What is the required active area of the detector?

    9. Do you required configurations with single, double or z stack MCP detectors? If you are not sure, your answers to the previous questions will help us to offer you the right configuration.

    https://www.dmphotonics.com/MCP_Detector_Basics/how_to_choose_mcp_detector.htm

    MCP-MA25/2 are used in aSPECT to study the background.

    1. Measuring the proton spectrum in neutron decay – latest results with aSPECT

    M. Simson, F. Ayala Guardia, S. Baeßler, M. Borg, F. Glück, W. Heil, I. Konorov, G. Konrad, R. Muñoz Horta, K.K.H. Leung, Yu. Sobolev, T. Soldner, H.-F. Wirth, O. Zimmer
    (Submitted on 24 Nov 2008)
    The retardation spectrometer aSPECT was built to measure the shape of the proton spectrum in free neutron decay with high precision. This allows us to determine the antineutrino electron angular correlation coefficient a. We aim for a precision more than one order of magnitude better than the present best value, which is Delta_a /a = 5%.
    In a recent beam time performed at the Institut Laue-Langevin during April / May 2008 we reached a statistical accuracy of about 2% per 24 hours measurement time. Several systematic effects were investigated experimentally. We expect the total relative uncertainty to be well below 5%.

    2. G. Konrad et al., “The Proton Spectrum in Neutron Beta Decay: Latest Results with the aSPECT Spectrometer”, Nucl. Physics A 827, 529c (2009)

    The Proton Spectrum in Neutron Beta Decay: First Results with the aSPECT spectrometer

    Baeßler, S.; Angerer, H.; Ayala Guardia, F.; Borg, M.; Eberhardt, K.; Glück, F.; Heil, W.; Konorov, I.; Konrad, G.; Luquero Llopis, N.; Muñoz Horta, R.; Orlowski, M.; Petzoldt, G.; Rich, D.; Simson, M.; Sobolev, Y.; Wirth, H. F.; Zimmer, O.
    INTERSECTIONS OF PARTICLE AND NUCLEAR PHYSICS: 9th Conference CIPAN2006. AIP Conference Proceedings, Volume 870, pp. 287-290 (2006).
    First measurements with the aSPECT spectrometer have been performed in a beam time at the beam line MEPHISTO of the neutron research reactor FRM-II. In this paper we give a short description of the spectrometer. The data analysis is underway.

    MCP detectors with metal anode are used in different applications. It is possible to detect and count electrons, positrons, protons, ions, Soft X-rays, x-rays, EUV,
    VUV- and UV-radiation.
    The flanges are equipped with 3 welded vacuum SHV high voltage feedthroughs.



    Automated Butt Fusion machines for pressure piping systems made of PE, PP, PB on building sites and in trenches in the dimensional range d 50 – 630 mm (6 sizes available). Hydraulic control unit with innovative design aluminium case and intuitive interface by means of an integrated colour touchscreen, to guide the operator from preparation to the end of the jointing process by use of big icons and clear messages. Automatic calculation, regulation and control of the fusion parameters – pressure, time and temperature – according to country specific guidelines. Distortion-free and sturdy base machine, providing high flexibility and fast set-up to adapt to different pipes/fittings configurations. Including transport packaging (wooden crate): reduction clamping inserts and other accessories to be ordered separately.

    For more information visit our website:

    https://www.gfps.com/appgate/ecat/common_flow/10005H/COM/en/109760/131021/297823/414473/414478/414479/414480/overview.html

    Imprint:

    https://www.gfps.com/content/gfps/com/en/service/footer/imprint.html

    Disclaimer:

    https://www.gfps.com/content/gfps/com/en/service/footer/disclaimer_gfps.html

    It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Mary from Uruguay - 2018.12.22 12:52
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Caroline from Denver - 2018.12.22 12:52

    Related Products

    WhatsApp Online Chat !