Renewable Design for 1D Metric Thread Bite Type Tube Fitting to Juventus Manufacturers
Renewable Design for 1D Metric Thread Bite Type Tube Fitting to Juventus Manufacturers Detail:
STRAIGHT REDUCERS
PART NOMBER
|
MPa
|
ØO D.
D1 D2 |
L1 |
L1 |
S1 |
S2
|
S3
|
bar
|
|
1C-08-06S |
S |
08 |
06 |
47 |
18.0 |
17 | 17 | 19 | 630 |
1C-10-06S |
|
10 |
06 |
48 |
17.5 |
19 | 17 | 22 | 630 |
1C-10-08S |
|
10 |
08 |
48 |
17.5 |
19 | 19 | 22 | 630 |
1C-12-06S |
|
12 |
06 |
50 |
19.5 |
22 | 17 | 24 | 630 |
1C-12-08S |
|
12 |
08 |
50 |
19.5 |
22 | 19 | 24 | 630 |
1C-12-10S |
|
12 |
10 |
51 |
19.0 |
22 | 22 | 24 | 630 |
1C-14-10S |
|
14 |
10 |
54 |
20.5 |
24 | 22 | 27 | 630 |
1C-14-12S |
|
14 |
12 |
54 |
20.5 |
24 | 24 | 27 | 630 |
1C-16-10S |
|
16 |
10 |
54 |
20.0 |
27 | 22 | 30 | 400 |
1C-16-12S |
|
16 |
12 |
54 |
20.0 |
27 | 24 | 30 | 400 |
1C-16-14S |
|
16 |
14 |
57 |
21.5 |
27 | 27 | 30 | 400 |
1C-20-10S |
|
20 |
10 |
60 |
22.0 |
32 | 22 | 36 | 400 |
1C-20-12S |
|
20 |
12 |
60 |
22.0 |
32 | 24 | 36 | 400 |
1C-20-16S |
|
20 |
16 |
63 |
23.0 |
32 | 30 | 36 | 400 |
1C-25-16S |
|
25 |
16 |
68 |
25.5 |
41 | 30 | 46 | 400 |
1C-25-20S |
|
25 |
20 |
71 |
25.5 |
41 | 36 | 46 | 400 |
1C-30-20S |
|
30 |
20 |
74 |
26.0 |
46 | 36 | 50 | 400 |
1C-30-25S |
|
30 |
25 |
77 |
26.5 |
46 | 46 | 50 | 400 |
1C-38-30S |
|
38 |
30 |
87 |
29.5 |
55 | 50 | 60 | 315 |
Product detail pictures:
Related Product Guide:
Tube Fittings and Pipe Fittings – Double Ferrule Tube Fittings
How to Replace a Hydraulic Hose Fitting
Our company since its inception, always regards product quality as enterprise life, continuously improve production technology, improve product quality and continuously strengthen enterprise total quality management, in strict accordance with the national standard ISO 9001:2000 for Renewable Design for 1D Metric Thread Bite Type Tube Fitting to Juventus Manufacturers, The product will supply to all over the world, such as: Algeria, Anguilla, Palestine, Company name, is always regarding quality as company' s foundation, seeking for development via high degree of credibility , abiding by ISO quality management standard strictly, creating top-ranking company by spirit of progress-marking honesty and optimism.
No freon refrigerant was in the ac system,if there is refrigerant take it to a local shop so they can remove it.Also vacum the system 30 mins to 1hr to get out moisture, before recharging the AC with r134a freon,add the correct amount,and dont forget to wear safety glasses and gloves.Check the fans if they come on or off also keep an eye on the temp gauge.
By Letitia from Uruguay - 2018.06.18 19:26
The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
By Esther from UK - 2018.02.04 14:13