Europe style for 22641-XX-XX Swaged Hose Fiting to Ukraine Factories

Short Description:

45° BSP O’RING FEMALE  60° CONE   PART NUMBER HOSE THREAD    T B mm L mm A mm M mm H2 mm   DN In SIZE             S226C1 – 04 – 04OR 6 1/4″ 04 1/4″ – 19 4 35,2 5,2 14,7 19 S226C1 – 06 – 06OR 10 3/8″ 06 3/8″ – 19 7 40,9 6 17,3 22 S226C1 – 08 – 08OR 12 1/2″ 08 1/2″ – 14 9,3 47,6 6,5 19,9 27 S226C2 – 10 – 10OR 16 5/8″ 10 5/8″ – 14 12 56,8 9,...


Product Detail

Product Tags

Related Video

Feedback (2)

Being supported by an innovative and experienced IT team, we could present technical support on pre-sales & after-sales service for Hydraulic Adapter For Sale, Gas Pipe Fittings Regulations, Interlok Hose And Fittings (Pty) Ltd, Created solutions with brand price. We attend seriously to produce and behave with integrity, and because of the favor of clients in your own home and overseas in the xxx industry.
Europe style for 22641-XX-XX Swaged Hose Fiting to Ukraine Factories Detail:

45° BSP O’RING FEMALE  60° CONE

123

 

PART NUMBER

HOSE

THREAD

   T

B

mm

L

mm

A

mm

M

mm

H2

mm

 

DN

In

SIZE

 

 

 

 

 

 

S226C1 – 04 – 04OR 6 1/4″ 04 1/4″ – 19 4 35,2 5,2 14,7 19
S226C1 – 06 – 06OR 10 3/8″ 06 3/8″ – 19 7 40,9 6 17,3 22
S226C1 – 08 – 08OR 12 1/2″ 08 1/2″ – 14 9,3 47,6 6,5 19,9 27
S226C2 – 10 – 10OR 16 5/8″ 10 5/8″ – 14 12 56,8 9,7 25,8 30
S226C2 – 12 – 12OR 20 3/4″ 12 3/4″ – 14 15 67,8 9 30,3 32
S226C2 – 16 – 16OR 25 1″ 16 1″ – 11 19,5 84,4 10,5 37,4 38
S226C2 – 16 – 20OR 25 1″ 16 1.1/4″ – 11 26 90,1 10,1 41,6 50
S226C2 – 20 – 20OR 32 1.1/4″ 20 1.1/4″ – 11 26 100,7 10,1 44,8 50
S226C2 – 20 – 24OR 32 1.1/4″ 20 1.1/2″ – 11 32 101,3 12,5 45,5 55
S226C2 – 24 – 24OR 40 1.1/2″ 24 1.1/2″ – 11 32 112,5 12,5 49 55
S226C2 – 24 – 32OR 40 1.1/2″ 24 2″ – 11 42 116 16,1 52,5 70
S226C2 – 32 – 32OR 50 2″ 32 2″ – 11 42 132,9 16,1 55,7 70

Product detail pictures:

Europe style for 22641-XX-XX Swaged Hose Fiting to Ukraine Factories detail pictures


Related Product Guide:
How to Replace a Hydraulic Hose Fitting
Tube Fittings and Pipe Fittings – Double Ferrule Tube Fittings

We're going to commit ourselves to giving our esteemed buyers using the most enthusiastically considerate solutions for Europe style for 22641-XX-XX Swaged Hose Fiting to Ukraine Factories, The product will supply to all over the world, such as: Swaziland, Austria, Kazakhstan, With the highest standards of product quality and service, our products have been exported to more than 25 countries like the USA, CANADA, GERMANY, FRANCE, UAE, Malaysia and so on.We are very pleased to serve customers from all over the world!


  • Shop our ductless systems online https://ingramswaterandair.com/heating-conditioning-ductless-mini-split-c-45_124.html

    A mini-split is ideal when you have limited space in which to work or the location to be cooled and heated lacks sufficient ductwork. And with a heat pump, you can achieve solid energy efficiencies that will save money.

    A basic mini-split is rated at least a 13 Seasonal Energy Efficiency Rating and some models can reach even higher SEERs. These units provide effective air comfort where you need them to while maintaining low energy consumption.

    A Ductless Mini-Split Heat Pump is not the most difficult HVAC system to install, but it is not something to take lightly. Proper installation is key for achieving the best energy efficiencies the unit can produce.

    By design, installation of the interior unit of a mini-split is relatively simplified. The most difficult electrical work is already done and housed safely within the system. What is required is properly mounting the unit itself on a wall and then running the various connections to the outdoor unit.

    Start by removing the wall mount from the back of the mini-split interior unit. Then, pick out a spot on a wall surface where you want the unit to be secured. After you have decided, use a level to mark out drill points and secure the wall mount according to instructions. You will have to drill holes that are level with one another. Through this process, be sure you have marked the area so that you know where you are going to drill.

    Measure twice, cut once. It’s a carpenter’s rule and it works here. For us, we want to measure twice and drill each hole once. One thing our interior walls probably do not need are unnecessary holes.

    After you have measured, drilled and installed the wall bracket, make sure the latch points are secure. The last thing you want is for the mini-split to tumble off the wall. Once the wall mount is ready, carefully unfold the refrigerant pipe making sure not to damage the tube in the process. Next, drill the hole for condensate drainage making sure to angle the hole slightly downward so gravity can do its job.

    It is important to note that you are going to combine the condensate tube, refrigerant line and conduit wire in the same bundle so you only have to have one hole going through your wall. Secure these together using tape and make sure the bundle is tightly packed to reduce needed space and making running them through the wall easier.

    Be careful not to damage the components in this process.

    Now, once the wall mount is ready, the condensate tube is attached, the refrigerant line is secure, plugs are installed, and the electrical cable has been run through you are ready to mount the interior unit on the wall. Lift the unit in to place making sure that the tube/line/cable combination pushes smoothly through the opening you drilled.

    After attachment to the wall mount the interior unit should be firmly secure and your refrigerant line, condensate tube and electrical cables should be run through the wall.

    It is time to install the outdoor unit.

    On a mini-split heat pump, the outdoor unit is composed of a condenser, efficient compressor and installation kit.

    Before beginning, you will need to decide how you want to place the outdoor unit. You can put it on a pad, mount it on an exterior wall or place it on a rooftop. Wherever you want to place your outdoor unit always remember to make sure it is properly secured before you make any connections between the interior and outdoor systems. For this video, we will be installing the outdoor unit on a pad.

    When the outdoor unit is properly placed on the pad and anchored you may remove the flare nuts from the surface valves. If you are using prefabricated line sets, then the flare nuts may be discarded, but if not they may be flared onto the lines that will be connected to the system.

    Before you start doing any cutting you need to make sure all the pieces are ready and you need to consider the proper tubing configuration. If the condenser is mounted higher than the air handler you must insure that there will be proper oil return to the compressor. You will need an inverted trap immediately exiting the condenser unit and additional oil traps for every 16 feet of vertical pipe run.

    With those requirements met, you are ready to cut. After you cut the copper tubing, be sure to clean the interior of the tube so there are no fragments remaining inside from the cutting process. Excess material left over may cause corrosion. Also, cut carefully so you do not dent the copper tubing.

    We carry a full line of ductless mini split units from 13 to 30 Seer . We offer free lifetime technical support and 24/7 phone service. Feel free to call us with any questions at 855-INGRAMS or 1-800-360-1569 , Visit BetterwayAC.com for more information on ductless mini split heat pumps and air conditioners.

    Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Ivy from Bogota - 2018.09.29 17:23
    The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Genevieve from Cancun - 2018.02.04 14:13

    Related Products

    WhatsApp Online Chat !